General purpose
Product Listing
-
Description:
Low-polarity phase: Crossbond™ 5% diphenyl / 95% dimethyl polysiloxane General -purpose columns for drugs, solvent impur i t ies, pesticides,hydrocarbons, PCB congeners (e.g., Aroclor mixes), essential oils, semi-volatiles. Equivalent to USP G27 and G36 phases. Similar phases: HP-5, DB-5, CP Sil 8 CB, SPB-5, Rtx-5
OUT OF STOCKLow-polarity phase: Crossbond™ 5% diphenyl / 95% dimethyl polysiloxane General -purpose columns for drugs, solvent impur i t ies, pesticides,hydrocarbons, PCB congeners (e.g., Aroclor mixes), essential oils, semi-volatiles. Equivalent to USP G27 and G36 phases. Similar phases: HP-5, DB-5, CP Sil 8 CB, SPB-5, Rtx-5
-
Description:
Low-polarity phase: Crossbond™ 5% diphenyl / 95% dimethyl polysiloxane General -purpose columns for drugs, solvent impur i t ies, pesticides,hydrocarbons, PCB congeners (e.g., Aroclor mixes), essential oils, semi-volatiles. Equivalent to USP G27 and G36 phases. Similar phases: HP-5, DB-5, CP Sil 8 CB, SPB-5, Rtx-5
OUT OF STOCKLow-polarity phase: Crossbond™ 5% diphenyl / 95% dimethyl polysiloxane General -purpose columns for drugs, solvent impur i t ies, pesticides,hydrocarbons, PCB congeners (e.g., Aroclor mixes), essential oils, semi-volatiles. Equivalent to USP G27 and G36 phases. Similar phases: HP-5, DB-5, CP Sil 8 CB, SPB-5, Rtx-5
-
Description:
High-polarity, stable polyethylene glycol (PEG) stationary phase. Low bleed and rugged enough to withstand repeated temperature cycles without retention time shifting. Ideal for food, flavor, fragrance, and industrial chemical and solvent analysis. Temperature range: 40 °C to 250/260 °C. Equivalent to USP G14, G15, G16, G20, and G39 phases. Similar phases: VF-WAXms, TR-WaxMS The SH-PolarWax MS column ensures reproducible retention times from run to run, even with temperature cycling. When methods require trace analysis, this highly polar, low-bleed stationary phase produces excellent signal-to-noise levels! Ideal for food and flavor analysis (e.g., essential oils), fragrance and allergen analysis, as well as industrial solvent and chemical analysis.
IN STOCKHigh-polarity, stable polyethylene glycol (PEG) stationary phase. Low bleed and rugged enough to withstand repeated temperature cycles without retention time shifting. Ideal for food, flavor, fragrance, and industrial chemical and solvent analysis. Temperature range: 40 °C to 250/260 °C. Equivalent to USP G14, G15, G16, G20, and G39 phases. Similar phases: VF-WAXms, TR-WaxMS The SH-PolarWax MS column ensures reproducible retention times from run to run, even with temperature cycling. When methods require trace analysis, this highly polar, low-bleed stationary phase produces excellent signal-to-noise levels! Ideal for food and flavor analysis (e.g., essential oils), fragrance and allergen analysis, as well as industrial solvent and chemical analysis.
-
Description:
High-polarity, stable polyethylene glycol (PEG) stationary phase. Low bleed and rugged enough to withstand repeated temperature cycles without retention time shifting. Ideal for food, flavor, fragrance, and industrial chemical and solvent analysis. Temperature range: 40 °C to 250/260 °C. Equivalent to USP G14, G15, G16, G20, and G39 phases. Similar phases: VF-WAXms, TR-WaxMS The SH-PolarWax MS column ensures reproducible retention times from run to run, even with temperature cycling. When methods require trace analysis, this highly polar, low-bleed stationary phase produces excellent signal-to-noise levels! Ideal for food and flavor analysis (e.g., essential oils), fragrance and allergen analysis, as well as industrial solvent and chemical analysis.
IN STOCKHigh-polarity, stable polyethylene glycol (PEG) stationary phase. Low bleed and rugged enough to withstand repeated temperature cycles without retention time shifting. Ideal for food, flavor, fragrance, and industrial chemical and solvent analysis. Temperature range: 40 °C to 250/260 °C. Equivalent to USP G14, G15, G16, G20, and G39 phases. Similar phases: VF-WAXms, TR-WaxMS The SH-PolarWax MS column ensures reproducible retention times from run to run, even with temperature cycling. When methods require trace analysis, this highly polar, low-bleed stationary phase produces excellent signal-to-noise levels! Ideal for food and flavor analysis (e.g., essential oils), fragrance and allergen analysis, as well as industrial solvent and chemical analysis.
-
Description:
Application-specific columns, specially tested for triglycerides. The SH-65TG phase resolves triglycerides by degree of unsaturation as well as by carbon number.
OUT OF STOCKApplication-specific columns, specially tested for triglycerides. The SH-65TG phase resolves triglycerides by degree of unsaturation as well as by carbon number.
-
Description:
Application-specific columns, specially tested for triglycerides. The SH-65TG phase resolves triglycerides by degree of unsaturation as well as by carbon number.
OUT OF STOCKApplication-specific columns, specially tested for triglycerides. The SH-65TG phase resolves triglycerides by degree of unsaturation as well as by carbon number.
-
Description:
Mid-polarity phase: Crossbond™ 25% diphenyl / 75% dimethyl polysiloxane General-purpose columns for volatile compounds, flavor compounds, alcoholic beverages.
OUT OF STOCKMid-polarity phase: Crossbond™ 25% diphenyl / 75% dimethyl polysiloxane General-purpose columns for volatile compounds, flavor compounds, alcoholic beverages.
-
Description:
Non-polar phase: Crossbond™ 100% dimethyl polysiloxane General-purpose columns for solvent impurities, PCB congeners (e.g., Aroclor mixes), simulated distillation, arson accelerants, gases, natural gas odorants, sulfur compounds, essential oils, hydrocarbons, semi-volatiles, pesticides, oxygenates. Equivalent to USP G1, G2, G38 phases. Similar phases: HP-1, DB-1, CP Sil 5 CB, SPB-1, Rtx-1
OUT OF STOCKNon-polar phase: Crossbond™ 100% dimethyl polysiloxane General-purpose columns for solvent impurities, PCB congeners (e.g., Aroclor mixes), simulated distillation, arson accelerants, gases, natural gas odorants, sulfur compounds, essential oils, hydrocarbons, semi-volatiles, pesticides, oxygenates. Equivalent to USP G1, G2, G38 phases. Similar phases: HP-1, DB-1, CP Sil 5 CB, SPB-1, Rtx-1
-
Description:
Mid-polarity phase: Crossbond™ 6% cyanopropylphenyl / 94% dimethyl polysiloxane Application-specific columns for volatile organic pollutants. Recommended in U.S. EPA methods for volatile organic pollutants. Equivalent to USP G43 phase. Similar phases: HP-624, DB-624, DB-624 UI, VF-624ms, SPB-1301
OUT OF STOCKMid-polarity phase: Crossbond™ 6% cyanopropylphenyl / 94% dimethyl polysiloxane Application-specific columns for volatile organic pollutants. Recommended in U.S. EPA methods for volatile organic pollutants. Equivalent to USP G43 phase. Similar phases: HP-624, DB-624, DB-624 UI, VF-624ms, SPB-1301
-
Description:
Non-polar phase: Crossbond™ 100% dimethyl polysiloxane General-purpose columns for solvent impurities, PCB congeners (e.g., Aroclor mixes), simulated distillation, arson accelerants, gases, natural gas odorants, sulfur compounds, essential oils, hydrocarbons, semi-volatiles, pesticides, oxygenates. Equivalent to USP G1, G2, G38 phases. Similar phases: HP-1, DB-1, CP Sil 5 CB, SPB-1, Rtx-1 Integrated Guard Columns No leaks for a more robust method. No column connections for easier, faster maintenance. No peak distortions due to connector dead volume and thermal capacity. For column without Integra-Guard column, please refer to 221-75732-30
OUT OF STOCKNon-polar phase: Crossbond™ 100% dimethyl polysiloxane General-purpose columns for solvent impurities, PCB congeners (e.g., Aroclor mixes), simulated distillation, arson accelerants, gases, natural gas odorants, sulfur compounds, essential oils, hydrocarbons, semi-volatiles, pesticides, oxygenates. Equivalent to USP G1, G2, G38 phases. Similar phases: HP-1, DB-1, CP Sil 5 CB, SPB-1, Rtx-1 Integrated Guard Columns No leaks for a more robust method. No column connections for easier, faster maintenance. No peak distortions due to connector dead volume and thermal capacity. For column without Integra-Guard column, please refer to 221-75732-30
-
Description:
General-purpose columns with unique selectivity for pesticides, PAHs, or other semivolatiles. Ideal for low/trace-level analyses. Low-bleed, high-resolution columns with unique selectivity.
OUT OF STOCKGeneral-purpose columns with unique selectivity for pesticides, PAHs, or other semivolatiles. Ideal for low/trace-level analyses. Low-bleed, high-resolution columns with unique selectivity.
-
Description:
Polar phase: Crossbond™ polyethylene glycol Low-bleed PEG column ensures long column lifetimes. Rugged enough to withstand repeated water injections. Equivalent to USP G14, G15, G16, G20, and G39 phases. Similar phases: Innowax, CP-Wax 52 CB, VF-WAX MS, Supelcowax-10
OUT OF STOCKPolar phase: Crossbond™ polyethylene glycol Low-bleed PEG column ensures long column lifetimes. Rugged enough to withstand repeated water injections. Equivalent to USP G14, G15, G16, G20, and G39 phases. Similar phases: Innowax, CP-Wax 52 CB, VF-WAX MS, Supelcowax-10