GC Columns



Product Listing

  • Product Part
    Description:

    Polar phase: Crossbond™ polyethylene glycol Low-bleed PEG column ensures long column lifetimes.  Rugged enough to withstand repeated water injections. Equivalent to USP G14, G15, G16, G20, and G39 phases. Similar phases: Innowax, CP-Wax 52 CB, VF-WAX MS, Supelcowax-10

    OUT OF STOCK

    Polar phase: Crossbond™ polyethylene glycol Low-bleed PEG column ensures long column lifetimes.  Rugged enough to withstand repeated water injections. Equivalent to USP G14, G15, G16, G20, and G39 phases. Similar phases: Innowax, CP-Wax 52 CB, VF-WAX MS, Supelcowax-10

  • Product Part
    Description:

    Polar phase: Crossbond™ polyethylene glycol Low-bleed PEG column ensures long column lifetimes.  Rugged enough to withstand repeated water injections. Equivalent to USP G14, G15, G16, G20, and G39 phases. Similar phases: Innowax, CP-Wax 52 CB, VF-WAX MS, Supelcowax-10

    OUT OF STOCK

    Polar phase: Crossbond™ polyethylene glycol Low-bleed PEG column ensures long column lifetimes.  Rugged enough to withstand repeated water injections. Equivalent to USP G14, G15, G16, G20, and G39 phases. Similar phases: Innowax, CP-Wax 52 CB, VF-WAX MS, Supelcowax-10

  • Product Part
    Description:

    Polar phase: Crossbond™ polyethylene glycol Low-bleed PEG column ensures long column lifetimes.  Rugged enough to withstand repeated water injections. Equivalent to USP G14, G15, G16, G20, and G39 phases. Similar phases: Innowax, CP-Wax 52 CB, VF-WAX MS, Supelcowax-10

    LOW STOCK

    Polar phase: Crossbond™ polyethylene glycol Low-bleed PEG column ensures long column lifetimes.  Rugged enough to withstand repeated water injections. Equivalent to USP G14, G15, G16, G20, and G39 phases. Similar phases: Innowax, CP-Wax 52 CB, VF-WAX MS, Supelcowax-10

  • Product Part
    Description:

    Mid-polarity phase: Crossbond™ 6% cyanopropylphenyl / 94% dimethyl polysiloxane Application-specific columns for volatile organic pollutants. Recommended in U.S. EPA methods for volatile organic pollutants. Equivalent to USP G43 phase. Similar phases: HP-624, DB-624, DB-624 UI, VF-624ms, SPB-1301

    OUT OF STOCK

    Mid-polarity phase: Crossbond™ 6% cyanopropylphenyl / 94% dimethyl polysiloxane Application-specific columns for volatile organic pollutants. Recommended in U.S. EPA methods for volatile organic pollutants. Equivalent to USP G43 phase. Similar phases: HP-624, DB-624, DB-624 UI, VF-624ms, SPB-1301

  • Product Part
    Description:

    Optimized column selectivities guarantee resolution of ethanol, internal standards, and frequently encountered interferences. Robust and reproducible column chemistry ensures longer column lifetime and consistent results. Ideal for analysis of alcohol compounds in blood

    LOW STOCK

    Optimized column selectivities guarantee resolution of ethanol, internal standards, and frequently encountered interferences. Robust and reproducible column chemistry ensures longer column lifetime and consistent results. Ideal for analysis of alcohol compounds in blood

  • Product Part
    Description:

    Optimized column selectivities guarantee resolution of ethanol, internal standards, and frequently encountered interferences. Robust and reproducible column chemistry ensures longer column lifetime and consistent results. Ideal for analysis of alcohol compounds in blood

    OUT OF STOCK

    Optimized column selectivities guarantee resolution of ethanol, internal standards, and frequently encountered interferences. Robust and reproducible column chemistry ensures longer column lifetime and consistent results. Ideal for analysis of alcohol compounds in blood

  • Product Part
    Description:

    SH-BAC2 Cap. Column 0.32mm, 1.2μm, 30m

    OUT OF STOCK

    SH-BAC2 Cap. Column 0.32mm, 1.2μm, 30m

  • Product Part
    Description:

    Optimized column selectivities guarantee resolution of ethanol, internal standards, and frequently encountered interferences. Robust and reproducible column chemistry ensures longer column lifetime and consistent results. Ideal for analysis of alcohol compounds in blood

    LOW STOCK

    Optimized column selectivities guarantee resolution of ethanol, internal standards, and frequently encountered interferences. Robust and reproducible column chemistry ensures longer column lifetime and consistent results. Ideal for analysis of alcohol compounds in blood

  • Product Part
    Description:

    Optimized column selectivities guarantee resolution of ethanol, internal standards, and frequently encountered interferences. Robust and reproducible column chemistry ensures longer column lifetime and consistent results. Ideal for analysis of alcohol compounds in blood

    OUT OF STOCK

    Optimized column selectivities guarantee resolution of ethanol, internal standards, and frequently encountered interferences. Robust and reproducible column chemistry ensures longer column lifetime and consistent results. Ideal for analysis of alcohol compounds in blood

  • Product Part
    Description:

    5% diphenyl / 95% dimethyl polysiloxane Optimized for PBDE analysis by EPA Method 1614. Short column option resolves BDE-209 three times faster, with less thermal breakdown. Unique deactivation gives higher BDE-209 response than competitor columns, for greater analytical sensitivity. Exceeds EPA Method 1614 resolution criteria for BDE-49 and BDE-71.

    OUT OF STOCK

    5% diphenyl / 95% dimethyl polysiloxane Optimized for PBDE analysis by EPA Method 1614. Short column option resolves BDE-209 three times faster, with less thermal breakdown. Unique deactivation gives higher BDE-209 response than competitor columns, for greater analytical sensitivity. Exceeds EPA Method 1614 resolution criteria for BDE-49 and BDE-71.

  • Product Part
    Description:

    5% diphenyl / 95% dimethyl polysiloxane Optimized for PBDE analysis by EPA Method 1614. Short column option resolves BDE-209 three times faster, with less thermal breakdown. Unique deactivation gives higher BDE-209 response than competitor columns, for greater analytical sensitivity. Exceeds EPA Method 1614 resolution criteria for BDE-49 and BDE-71.

    LOW STOCK

    5% diphenyl / 95% dimethyl polysiloxane Optimized for PBDE analysis by EPA Method 1614. Short column option resolves BDE-209 three times faster, with less thermal breakdown. Unique deactivation gives higher BDE-209 response than competitor columns, for greater analytical sensitivity. Exceeds EPA Method 1614 resolution criteria for BDE-49 and BDE-71.

  • Product Part
    Description:

    Dedicated columns for organochlorine pesticides and herbicides. Low bleed - ideal for high-sensitivity GC-ECD or GCMS analyses. Baseline separations in less than 10 minutes. Analyze EPA Method 8081B, 8082A, 8151A, 504.1, 515, 508.1, and 552.2 compounds without time-consuming column changes. Similar phases: DB-CLP1 / DB-CLP2

    OUT OF STOCK

    Dedicated columns for organochlorine pesticides and herbicides. Low bleed - ideal for high-sensitivity GC-ECD or GCMS analyses. Baseline separations in less than 10 minutes. Analyze EPA Method 8081B, 8082A, 8151A, 504.1, 515, 508.1, and 552.2 compounds without time-consuming column changes. Similar phases: DB-CLP1 / DB-CLP2


Leading Supplier for GC Column & Customised GC Column in Singapore

Gas chromatography, or GC, is undoubtedly one of the essential techniques in separating volatile compounds. It is helpful in the fields of health, medicine, drug analysis, food science, and more. It plays a crucial role in the fields of food and agriculture, industrial and environment, energy and chemical. Therefore, it requires precision and infallible GC columns to ensure attested analysis.

At Shimadzu, we ensure our GC consumables span a broad range to suit your analytical needs. We provide GC columns, PLOT columns and customised GC columns. Our GC column provides the best solution for most applications giving reliable and reproducible results.

Highly Reproducible Results and Accuracy

Our GC columns and consumables are designed to complete your Shimadzu GC System. Shimadzu understands your chromatography analysis does not end with the selection of the GC column. The combination of components selected for your Shimadzu instrument makes an important contribution to successful chromatography. Shimadzu GC columns are designed to provide you with the best separation performance with highly reproducible and reliable results for your GC applications.

Accurate Peak Identification and Quantification in GC Analysis with Shimadzu GC Columns

Elevate your GC analysis with Shimadzu GC Columns, designed to ensure precise peak identification and quantification. Our columns are engineered using cutting-edge technology, delivering exceptional separation capabilities. Whether you're dealing with complex samples or routine analyses, Shimadzu GC Columns provide the accuracy you need to confidently identify and quantify peaks. Trust in our columns to deliver reliable results, enabling you to achieve the highest standards of analytical excellence in your chromatographic endeavors.

High-Quality Materials for Optimal Performance

Shimadzu prioritises quality and performance when it comes to the materials used in our GC columns. We carefully select premium-grade materials with excellent thermal stability, low bleed characteristics, and high inertness. Using these high-quality materials ensures optimal column performance, minimising background interference and maximising sensitivity for your capillary column GC applications.

Versatile Applications for Diverse Needs

Shimadzu has a wide range of GC Columns available including Fused Silica Capillary Columns, Fused Silica PLOT Columns, Stainless Steel Columns, Guard Columns and application specific columns. Whether you require analysis in pharmaceuticals, environmental testing, food and beverages, or materials science, our GC columns are designed to deliver accurate and precise results. Shimadzu GC columns are manufactured to the highest industry standard and designed to provide excellent chromatographic performance, reproducibility and lifetime complementing any GC/GC-MS instrument.

GC Guard Columns for Enhanced Protection

For enhanced performance and extended column life, Shimadzu also offers GC guard columns. These columns act as protective barriers, shielding the primary GC column by capturing contaminants or particles. By utilising a guard column, you can increase the lifespan of the GC column and save costs. 

Customised Solutions for Specific Requirements

Shimadzu understands that each GC column application is unique, and specific requirements may arise. That's why we offer customised GC columns tailored to your particular needs. Our team of experts collaborates closely with you to have a clear idea of your application and recommend or develop a custom GC column that meets your precise specifications. This personalised approach ensures you achieve optimal results and efficiency in your analytical processes.

Reliable GC Column Application at Shimadzu

GC columns and customised GC columns are the solutions to various GC column applications. In order to cater to your GC application requirements, Shimadzu offers a wide range and high-quality GC columns, capillary columns, metal columns, PLOT, and customised GC columns. We can provide you with dedicated capillary columns for GC used for pesticide analysis, analysis of fatty acid methyl esters (FAME) analysis, blood alcohol analysis, PCB analysis, volatile amine analysis and many other GC applications.

High performance columns for highest inertness and excellent performance

Shimadzu’s series of high-quality capillary columns provides the highest inertness and excellent performance. Our high-performance columns deliver exceptional temperature stability, leading to minimal bleeding properties and heightened system sensitivity. This enables achieving reduced limits of detection (LOD), quicker system stabilization, and shortened conditioning times.

Metal Columns: Ideal for Specific Applications

Shimadzu's metal columns are specially designed for specific applications that require unique characteristics not found in traditional columns. Metal columns offer superior performance in applications such as sulphur compounds, permanent gases, and metal analyses. These GC columns provide excellent stability, robustness, and selectivity, enabling precise analysis of challenging samples in various industries.

PLOT Columns: Enhanced Separation for Complex Matrices

Our PLOT (Porous Layer Open Tubular) columns excel in analysing complex matrices and volatile compounds. The unique porous structure of PLOT columns allows for enhanced separation and analysis of typically difficult to resolve components. These columns are particularly suited for environmental analysis, forensic analysis, and volatile organic compounds (VOCs) analysis. PLOT columns offer superior retention capacity and can withstand challenging sample matrices, ensuring accurate and reliable results.

Dedicated columns for dedicated applications and analytes

In order to solve chromatographic challenges, we provide an array of specific GC columns for dedicated applications like EPA methods, food analysis, clinical samples and more. These columns and stationary phases have been fine-tuned and rigorously tested to deliver optimal separation, precise quantification, and rapid analysis durations.

Customisation of GC Columns same as Customised Solutions for Specific Requirements???

Each analytical challenge is unique; sometimes, standard GC columns may only partially meet your specific requirements. Shimadzu offers customisation services for GC columns, allowing you to tailor the column to your specifications.

Our customised GC columns are available in either glass or stainless-steel tubing, and you can choose the diameter, length, solid support material, coated phase, and mesh size that best suits your analytical needs. By submitting your request for a customised GC column to Shimadzu, you can enhance the performance and efficiency of your analyses by obtaining a column GC designed specifically for your application.

H2GC Guard Column and Retention Gap Column Supplier Based in Singapore

Shimadzu GC guard columns and retention gap columns can be used for a varied range of applications and extend the lifetime of a column. These GC guard columns are compatible with the most commonly used solvents. They are manufactured and individually tested to ensure accuracy, inertness, and outstanding performance.

Trust Shimadzu for your GC column and customised GC column needs. We have an extensive catalogue of GC consumables that can help you stock up on your lab consumables. Contact us today and we will assist you in selecting the right GC column and consumables for your GC column applications.

Frequently Asked Questions About GC Columns

1. What is the function of a GC column?

Gas chromatography (GC) columns are essential to gas chromatography as they are used in separating complex mixtures. It is a crucial tool used and applied in analytical chemistry as it is efficient, and effective. It is made up of a glass-like material called fused silica coated with a layer of stationary phase that interacts with the analytes as it goes through the column. This interaction results in the separation of the more volatile compounds from the less volatile ones.

2. What are the types of GC columns?

There are two types of gas chromatography (GC) columns - packed columns and capillary columns. Packed columns are short and thick columns made of stainless steel or glass. These GC columns have low separation performance and create broad, peaked shapes in the chromatogram. Packed columns are less susceptible to contamination and can handle larger sample volumes.

Capillary columns are currently the most common GC column type. These columns have superior separation performance and are ideal for highly sensitive separation and analysis. Capillary columns create sharper peaks resulting in higher sensitivity and lower detection limit.