    Description:

    Polar phase: Crossbond™ acid-deactivated Carbowax™ polyethylene glycol Dedicated columns for free (underivatized) acids, some inorganic acids. Resistant to oxidative damage. Equivalent to USP G25 and G35 phases. Similar phases: HP-FFAP, DB-FFAP, VF-DA, CP-Wax 58 CB, CP-FFAP CB, Nukol

    LOW STOCK

    Polar phase: Crossbond™ acid-deactivated Carbowax™ polyethylene glycol Dedicated columns for free (underivatized) acids, some inorganic acids. Resistant to oxidative damage. Equivalent to USP G25 and G35 phases. Similar phases: HP-FFAP, DB-FFAP, VF-DA, CP-Wax 58 CB, CP-FFAP CB, Nukol

  • Product Part
    Description:

    High-polarity, stable polyethylene glycol (PEG) stationary phase. Low bleed and rugged enough to withstand repeated temperature cycles without retention time shifting. Ideal for food, flavor, fragrance, and industrial chemical and solvent analysis. Temperature range: 40 °C to 250/260 °C. Equivalent to USP G14, G15, G16, G20, and G39 phases. Similar phases: VF-WAXms, TR-WaxMS The SH-PolarWax MS column ensures reproducible retention times from run to run, even with temperature cycling. When methods require trace analysis, this highly polar, low-bleed stationary phase produces excellent signal-to-noise levels! Ideal for food and flavor analysis (e.g., essential oils), fragrance and allergen analysis, as well as industrial solvent and chemical analysis.

    High-polarity, stable polyethylene glycol (PEG) stationary phase. Low bleed and rugged enough to withstand repeated temperature cycles without retention time shifting. Ideal for food, flavor, fragrance, and industrial chemical and solvent analysis. Temperature range: 40 °C to 250/260 °C. Equivalent to USP G14, G15, G16, G20, and G39 phases. Similar phases: VF-WAXms, TR-WaxMS The SH-PolarWax MS column ensures reproducible retention times from run to run, even with temperature cycling. When methods require trace analysis, this highly polar, low-bleed stationary phase produces excellent signal-to-noise levels! Ideal for food and flavor analysis (e.g., essential oils), fragrance and allergen analysis, as well as industrial solvent and chemical analysis.

  • Product Part
    Description:

    Low-polarity phase: Crossbond™ 5% diphenyl / 95% dimethyl polysiloxane Dedicated columns for amines and other basic compounds, including alkylamines, diamines, triamines, ethanolamines, and nitrogen-containing heterocyclics.

    OUT OF STOCK

    Low-polarity phase: Crossbond™ 5% diphenyl / 95% dimethyl polysiloxane Dedicated columns for amines and other basic compounds, including alkylamines, diamines, triamines, ethanolamines, and nitrogen-containing heterocyclics.

  • Product Part
    Description:

    Low-polarity phase: Crossbond™ 5% diphenyl / 95% dimethyl polysiloxane Dedicated columns for amines and other basic compounds, including alkylamines, diamines, triamines, ethanolamines, and nitrogen-containing heterocyclics.

    OUT OF STOCK

    Low-polarity phase: Crossbond™ 5% diphenyl / 95% dimethyl polysiloxane Dedicated columns for amines and other basic compounds, including alkylamines, diamines, triamines, ethanolamines, and nitrogen-containing heterocyclics.

  • Product Part
    Description:

    Dedicated column for FAMEs, specially tested with a FAME mixture. Equivalent to USP G16 phase. Similar phases: Select FAME, Omegawax

    LOW STOCK

    Dedicated column for FAMEs, specially tested with a FAME mixture. Equivalent to USP G16 phase. Similar phases: Select FAME, Omegawax

  • Product Part
    Description:

    Application-specific columns, specially tested for triglycerides. The SH-65TG phase resolves triglycerides by degree of unsaturation as well as by carbon number.

    OUT OF STOCK

    Application-specific columns, specially tested for triglycerides. The SH-65TG phase resolves triglycerides by degree of unsaturation as well as by carbon number.

  • Product Part
    Description:

    Application-specific columns, specially tested for triglycerides. The SH-65TG phase resolves triglycerides by degree of unsaturation as well as by carbon number.

    OUT OF STOCK

    Application-specific columns, specially tested for triglycerides. The SH-65TG phase resolves triglycerides by degree of unsaturation as well as by carbon number.

  • Product Part
    Description:

    Unique selectivity for baseline resolution of all volatile amines. Excellent inertness assures accuracy and sensitivity for volatile amines, including free ammonia. Highly robust phase withstands repeated water injections, resulting in longer column lifetime. High temperature stability (290 °C) ensures elution of amines up to C16 and allows contaminants to be removed by "baking out" the column. Similar phase: CP-Volamine The SH-Volatile Amine column was designed specifically for analyzing volatile amines in difficult matrices, such as water. The unique base deactivation creates an exceptionally inert surface for these sensitive compounds, resulting in highly symmetrical peaks, which allow low detection limits. The stable bonded phase yields a column that is not only retentive and highly selective for these compounds but is also very robust and able to withstand repeated water injections.

    OUT OF STOCK

    Unique selectivity for baseline resolution of all volatile amines. Excellent inertness assures accuracy and sensitivity for volatile amines, including free ammonia. Highly robust phase withstands repeated water injections, resulting in longer column lifetime. High temperature stability (290 °C) ensures elution of amines up to C16 and allows contaminants to be removed by "baking out" the column. Similar phase: CP-Volamine The SH-Volatile Amine column was designed specifically for analyzing volatile amines in difficult matrices, such as water. The unique base deactivation creates an exceptionally inert surface for these sensitive compounds, resulting in highly symmetrical peaks, which allow low detection limits. The stable bonded phase yields a column that is not only retentive and highly selective for these compounds but is also very robust and able to withstand repeated water injections.

  • Product Part
    Description:

    Unique selectivity for baseline resolution of all volatile amines. Excellent inertness assures accuracy and sensitivity for volatile amines, including free ammonia. Highly robust phase withstands repeated water injections, resulting in longer column lifetime. High temperature stability (290 °C) ensures elution of amines up to C16 and allows contaminants to be removed by "baking out" the column. Similar phase: CP-Volamine The SH-Volatile Amine column was designed specifically for analyzing volatile amines in difficult matrices, such as water. The unique base deactivation creates an exceptionally inert surface for these sensitive compounds, resulting in highly symmetrical peaks, which allow low detection limits. The stable bonded phase yields a column that is not only retentive and highly selective for these compounds but is also very robust and able to withstand repeated water injections.

    LOW STOCK

    Unique selectivity for baseline resolution of all volatile amines. Excellent inertness assures accuracy and sensitivity for volatile amines, including free ammonia. Highly robust phase withstands repeated water injections, resulting in longer column lifetime. High temperature stability (290 °C) ensures elution of amines up to C16 and allows contaminants to be removed by "baking out" the column. Similar phase: CP-Volamine The SH-Volatile Amine column was designed specifically for analyzing volatile amines in difficult matrices, such as water. The unique base deactivation creates an exceptionally inert surface for these sensitive compounds, resulting in highly symmetrical peaks, which allow low detection limits. The stable bonded phase yields a column that is not only retentive and highly selective for these compounds but is also very robust and able to withstand repeated water injections.

  • Product Part
    Description:

    Polar PLOT column, incorporating divinylbenzene ethylene glycol / dimethylacrylate. Highest polarity porous polymer column in Shimadzu PLOT columns. Highly inert for the analysis of polar and nonpolar compounds. Ideal for trace H2S, COS, and mercaptans in hydrocarbon streams. Temp. range up 190 °C Similar phases: HP-PLOT U, CP-PoraPLOT U, CP-PoraBOND U, Rt-U-BOND

    OUT OF STOCK

    Polar PLOT column, incorporating divinylbenzene ethylene glycol / dimethylacrylate. Highest polarity porous polymer column in Shimadzu PLOT columns. Highly inert for the analysis of polar and nonpolar compounds. Ideal for trace H2S, COS, and mercaptans in hydrocarbon streams. Temp. range up 190 °C Similar phases: HP-PLOT U, CP-PoraPLOT U, CP-PoraBOND U, Rt-U-BOND

  • Product Part
    Description:

    Na2SO4 deactivation Acetylene and propadiene elute after butanes. Best separation for butene isomers (impurities in butene streams). Methyl acetylene elutes after 1,3-butadiene. Cyclopropane (impurity in propylene) elutes well before propylene. Temp. range up to 200 °C Similar phases: GS-ALUMINA, CP-Al2O3/Na2SO4, Alumina sulfate PLOT, Rt-Alumina BOND/Na2SO4

    LOW STOCK

    Na2SO4 deactivation Acetylene and propadiene elute after butanes. Best separation for butene isomers (impurities in butene streams). Methyl acetylene elutes after 1,3-butadiene. Cyclopropane (impurity in propylene) elutes well before propylene. Temp. range up to 200 °C Similar phases: GS-ALUMINA, CP-Al2O3/Na2SO4, Alumina sulfate PLOT, Rt-Alumina BOND/Na2SO4

  • Product Part
    Description:

    Mid-polarity phase: Crossbond™ 25% diphenyl / 75% dimethyl polysiloxane General-purpose columns for volatile compounds, flavor compounds, alcoholic beverages.

    OUT OF STOCK

    Mid-polarity phase: Crossbond™ 25% diphenyl / 75% dimethyl polysiloxane General-purpose columns for volatile compounds, flavor compounds, alcoholic beverages.


Leading Supplier for GC Column & Customised GC Column in Singapore

Gas chromatography, or GC, is undoubtedly one of the essential techniques in separating volatile compounds. It is helpful in the fields of health, medicine, drug analysis, food science, and more. It plays a crucial role in the fields of food and agriculture, industrial and environment, energy and chemical. Therefore, it requires precision and infallible GC columns to ensure attested analysis.

At Shimadzu, we ensure our GC consumables span a broad range to suit your analytical needs. We provide GC columns, PLOT columns and customised GC columns. Our GC column provides the best solution for most applications giving reliable and reproducible results.

Highly Reproducible Results and Accuracy

Our GC columns and consumables are designed to complete your Shimadzu GC System. Shimadzu understands your chromatography analysis does not end with the selection of the GC column. The combination of components selected for your Shimadzu instrument makes an important contribution to successful chromatography. Shimadzu GC columns are designed to provide you with the best separation performance with highly reproducible and reliable results for your GC applications.

Accurate Peak Identification and Quantification in GC Analysis with Shimadzu GC Columns

Elevate your GC analysis with Shimadzu GC Columns, designed to ensure precise peak identification and quantification. Our columns are engineered using cutting-edge technology, delivering exceptional separation capabilities. Whether you're dealing with complex samples or routine analyses, Shimadzu GC Columns provide the accuracy you need to confidently identify and quantify peaks. Trust in our columns to deliver reliable results, enabling you to achieve the highest standards of analytical excellence in your chromatographic endeavors.

High-Quality Materials for Optimal Performance

Shimadzu prioritises quality and performance when it comes to the materials used in our GC columns. We carefully select premium-grade materials with excellent thermal stability, low bleed characteristics, and high inertness. Using these high-quality materials ensures optimal column performance, minimising background interference and maximising sensitivity for your capillary column GC applications.

Versatile Applications for Diverse Needs

Shimadzu has a wide range of GC Columns available including Fused Silica Capillary Columns, Fused Silica PLOT Columns, Stainless Steel Columns, Guard Columns and application specific columns. Whether you require analysis in pharmaceuticals, environmental testing, food and beverages, or materials science, our GC columns are designed to deliver accurate and precise results. Shimadzu GC columns are manufactured to the highest industry standard and designed to provide excellent chromatographic performance, reproducibility and lifetime complementing any GC/GC-MS instrument.

GC Guard Columns for Enhanced Protection

For enhanced performance and extended column life, Shimadzu also offers GC guard columns. These columns act as protective barriers, shielding the primary GC column by capturing contaminants or particles. By utilising a guard column, you can increase the lifespan of the GC column and save costs. 

Customised Solutions for Specific Requirements

Shimadzu understands that each GC column application is unique, and specific requirements may arise. That's why we offer customised GC columns tailored to your particular needs. Our team of experts collaborates closely with you to have a clear idea of your application and recommend or develop a custom GC column that meets your precise specifications. This personalised approach ensures you achieve optimal results and efficiency in your analytical processes.

Reliable GC Column Application at Shimadzu

GC columns and customised GC columns are the solutions to various GC column applications. In order to cater to your GC application requirements, Shimadzu offers a wide range and high-quality GC columns, capillary columns, metal columns, PLOT, and customised GC columns. We can provide you with dedicated capillary columns for GC used for pesticide analysis, analysis of fatty acid methyl esters (FAME) analysis, blood alcohol analysis, PCB analysis, volatile amine analysis and many other GC applications.

High performance columns for highest inertness and excellent performance

Shimadzu’s series of high-quality capillary columns provides the highest inertness and excellent performance. Our high-performance columns deliver exceptional temperature stability, leading to minimal bleeding properties and heightened system sensitivity. This enables achieving reduced limits of detection (LOD), quicker system stabilization, and shortened conditioning times.

Metal Columns: Ideal for Specific Applications

Shimadzu's metal columns are specially designed for specific applications that require unique characteristics not found in traditional columns. Metal columns offer superior performance in applications such as sulphur compounds, permanent gases, and metal analyses. These GC columns provide excellent stability, robustness, and selectivity, enabling precise analysis of challenging samples in various industries.

PLOT Columns: Enhanced Separation for Complex Matrices

Our PLOT (Porous Layer Open Tubular) columns excel in analysing complex matrices and volatile compounds. The unique porous structure of PLOT columns allows for enhanced separation and analysis of typically difficult to resolve components. These columns are particularly suited for environmental analysis, forensic analysis, and volatile organic compounds (VOCs) analysis. PLOT columns offer superior retention capacity and can withstand challenging sample matrices, ensuring accurate and reliable results.

Dedicated columns for dedicated applications and analytes

In order to solve chromatographic challenges, we provide an array of specific GC columns for dedicated applications like EPA methods, food analysis, clinical samples and more. These columns and stationary phases have been fine-tuned and rigorously tested to deliver optimal separation, precise quantification, and rapid analysis durations.

Customisation of GC Columns same as Customised Solutions for Specific Requirements???

Each analytical challenge is unique; sometimes, standard GC columns may only partially meet your specific requirements. Shimadzu offers customisation services for GC columns, allowing you to tailor the column to your specifications.

Our customised GC columns are available in either glass or stainless-steel tubing, and you can choose the diameter, length, solid support material, coated phase, and mesh size that best suits your analytical needs. By submitting your request for a customised GC column to Shimadzu, you can enhance the performance and efficiency of your analyses by obtaining a column GC designed specifically for your application.

H2GC Guard Column and Retention Gap Column Supplier Based in Singapore

Shimadzu GC guard columns and retention gap columns can be used for a varied range of applications and extend the lifetime of a column. These GC guard columns are compatible with the most commonly used solvents. They are manufactured and individually tested to ensure accuracy, inertness, and outstanding performance.

Trust Shimadzu for your GC column and customised GC column needs. We have an extensive catalogue of GC consumables that can help you stock up on your lab consumables. Contact us today and we will assist you in selecting the right GC column and consumables for your GC column applications.

Frequently Asked Questions About GC Columns

1. What is the function of a GC column?

Gas chromatography (GC) columns are essential to gas chromatography as they are used in separating complex mixtures. It is a crucial tool used and applied in analytical chemistry as it is efficient, and effective. It is made up of a glass-like material called fused silica coated with a layer of stationary phase that interacts with the analytes as it goes through the column. This interaction results in the separation of the more volatile compounds from the less volatile ones.

2. What are the types of GC columns?

There are two types of gas chromatography (GC) columns - packed columns and capillary columns. Packed columns are short and thick columns made of stainless steel or glass. These GC columns have low separation performance and create broad, peaked shapes in the chromatogram. Packed columns are less susceptible to contamination and can handle larger sample volumes.