Scepter_1

Shim-pack Scepter C4-300, 5um, 30x75

Part Number: 227-31186-02

Particle size (µm): 5

ID (mm): 30

Length (mm): 75

USP: L26

Functional Group: C4

Mode: Reversed Phase

Type: Preparative columns

Guard Column: 227-31196-01

Guard Column Holder: 227-31171-03

Pore size (nm): 30

End Capping: Yes

Carbon Load (%): 9

PH: 1 - 10

Pressure Tolerance (MPa): 30

Pack size: 1

Column Name: Scepter C4-300

Lead Time: 4 - 6 weeks

Shim-pack Scepter Preparative Columns

Shim-pack Scepter C4-300 is wide-pore organic silica hybrid reversed phase columns recommended for the separation of proteins such as monoclonal antibodies and mid-sized molecules such as oligonucleic acids and peptides that may not be retained on 100-120Å pore size columns due to size-exclusion effects. The organic silica hybrid base material is highly stable even at high temperatures under acidic and basic mobile phase conditions. Pore sizes are optimized for large molecular weight compounds and dispersed uniformly in the column, resulting in symmetrical peak shapes and increased resolution of antibodies and nucleic acids compared to a smaller pore size column. Shim-pack Scepter C4-300 is also effective for high-sensitivity LC/MS analysis, producing good peak shapes even under weak ionpairing conditions using a formic acid mobile phase

Monoclonal Antibody Subunit Analysis

Recommended Products

Scepter_1
Shim-pack Scepter C4-300, 5um, 2.1x75

Part No.: 227-31180-04

Shim-pack Scepter

Shim-pack Scepter C4-300 is wide-pore organic silica hybrid reversed phase columns recommended for the separation of proteins such as monoclonal antibodies and mid-sized molecules such as oligonucleic acids and peptides that may not be retained on 100-120Å pore size columns due to size-exclusion effects. The organic silica hybrid base material is highly stable even at high temperatures under acidic and basic mobile phase conditions. Pore sizes are optimized for large molecular weight compounds and dispersed uniformly in the column, resulting in symmetrical peak shapes and increased resolution of antibodies and nucleic acids compared to a smaller pore size column. Shim-pack Scepter C4-300 is also effective for high-sensitivity LC/MS analysis, producing good peak shapes even under weak ionpairing conditions using a formic acid mobile phase Peptide Analysis Example Shim-pack Scepter C18-300 and C4-300 made with 300 Å (30 nm) pore size packing material. The larger pore size is recommended for the analysis of mid-sized and large-sized molecules with molecular weights above 5000 to enable retention and avoid size-exclusion effects. This analysis of a mixed sample of four different peptides and proteins demonstrated good peak shapes and favorable separation of insulin and ribonuclease A due to the pore size that was large enough to allow proper diffusion of these large molecular weight compounds.  

View product
Scepter_1
Shim-pack Scepter C4-300, 5um, 4.6x75

Part No.: 227-31183-03

Shim-pack Scepter

Shim-pack Scepter C4-300 is wide-pore organic silica hybrid reversed phase columns recommended for the separation of proteins such as monoclonal antibodies and mid-sized molecules such as oligonucleic acids and peptides that may not be retained on 100-120Å pore size columns due to size-exclusion effects. The organic silica hybrid base material is highly stable even at high temperatures under acidic and basic mobile phase conditions. Pore sizes are optimized for large molecular weight compounds and dispersed uniformly in the column, resulting in symmetrical peak shapes and increased resolution of antibodies and nucleic acids compared to a smaller pore size column. Shim-pack Scepter C4-300 is also effective for high-sensitivity LC/MS analysis, producing good peak shapes even under weak ionpairing conditions using a formic acid mobile phase Peptide Analysis Example Shim-pack Scepter C18-300 and C4-300 made with 300 Å (30 nm) pore size packing material. The larger pore size is recommended for the analysis of mid-sized and large-sized molecules with molecular weights above 5000 to enable retention and avoid size-exclusion effects. This analysis of a mixed sample of four different peptides and proteins demonstrated good peak shapes and favorable separation of insulin and ribonuclease A due to the pore size that was large enough to allow proper diffusion of these large molecular weight compounds.  

View product