Scepter_1
Scepter_1

Shim-pack Scepter Claris Phenyl-120, 3um, 2.1x150

Part Number: 227-31215-06

Column Name: Scepter Claris Phenyl-120

Particle size (µm): 3

ID (mm): 2.1

Length (mm): 150

USP: L11

Functional Group: Phenyl

Mode: Reversed Phase

Type: Analytical column (Bioinert)

Pore size (nm): 12

End Capping: Yes

Carbon Load (%): 17

PH: 1 to 10

Pressure Tolerance (MPa): 45

Pack size: 1

Lead Time: 4 - 6 weeks

Shim-pack Scepter Claris features a column body with a newly-developed bioinert coating packed with Scepter series stationary phases.


        
  • Bioinert coating is applied to the column body and stainless steel frit

  •     
  • Ideal for analysis of metal-coordinating and hydrophobically adsorbing compounds such as nucleic acids, proteins, and lipids

  •     
  • Outstanding pH and lifetime stability due to Scepter organic silica hybrid packing

 

Superior Sensitivity and Separation Performance in Nucleic Acid Analysis

Shim-pack Scepter Claris C18-120 with the bioinert coating and Scepter C18-120 with traditional stainless steel hardware were compared in this example of an analysis of a synthetic oligonucleotide. Results from Claris were highly sensitive and reproducible from the rst injection, with no loss of sample signal. Scepter C18-120 in a stainless steel column body produced low-sensitivity results and showed adsorption from the first sample injection.

Outstanding Performance in Oligonucleic Acid Analysis

Shim-pack Scepter Claris C18-120 (bioinert coating) and Scepter C18-20 (stainless steel body) were compared in this analysis of Oligodeoxythymidylic acid [d(T)20]. Results from Scepter C18-120 show low peak intensity, suggesting adsorption on metal surfaces. In contrast, Scepter Claris C18-120 produced a sharper and high-intensity peak.

Improved Sensitivity and Separation of Phospholipids

Shim-pack Scepter Claris C18-120 minimizes metal-mediated adsorption and hydrophobic absorption on the column surfaces, resulting in high-resolution separations. In this example of structurally complex phosphatidylcholine isomers, Scepter Claris C18-120 achieved increased baseline resolution between isomers with higher sensitivity.

 


 

Recommended Products

Scepter_1
Shim-pack Scepter Claris Phenyl-120, 3um, 2.1x50

Part No.: 227-31215-04

Shim-pack Scepter

Shim-pack Scepter Claris features a column body with a newly-developed bioinert coating packed with Scepter series stationary phases. Bioinert coating is applied to the column body and stainless steel frit Ideal for analysis of metal-coordinating and hydrophobically adsorbing compounds such as nucleic acids, proteins, and lipids Outstanding pH and lifetime stability due to Scepter organic silica hybrid packing   Superior Sensitivity and Separation Performance in Nucleic Acid Analysis Shim-pack Scepter Claris C18-120 with the bioinert coating and Scepter C18-120 with traditional stainless steel hardware were compared in this example of an analysis of a synthetic oligonucleotide. Results from Claris were highly sensitive and reproducible from the rst injection, with no loss of sample signal. Scepter C18-120 in a stainless steel column body produced low-sensitivity results and showed adsorption from the first sample injection. Outstanding Performance in Oligonucleic Acid Analysis Shim-pack Scepter Claris C18-120 (bioinert coating) and Scepter C18-20 (stainless steel body) were compared in this analysis of Oligodeoxythymidylic acid [d(T)20]. Results from Scepter C18-120 show low peak intensity, suggesting adsorption on metal surfaces. In contrast, Scepter Claris C18-120 produced a sharper and high-intensity peak. Improved Sensitivity and Separation of Phospholipids Shim-pack Scepter Claris C18-120 minimizes metal-mediated adsorption and hydrophobic absorption on the column surfaces, resulting in high-resolution separations. In this example of structurally complex phosphatidylcholine isomers, Scepter Claris C18-120 achieved increased baseline resolution between isomers with higher sensitivity.  

View product
Scepter_1
Shim-pack Scepter Claris Phenyl-120, 3um, 2.1x100

Part No.: 227-31215-05

Shim-pack Scepter

Shim-pack Scepter Claris features a column body with a newly-developed bioinert coating packed with Scepter series stationary phases. Bioinert coating is applied to the column body and stainless steel frit Ideal for analysis of metal-coordinating and hydrophobically adsorbing compounds such as nucleic acids, proteins, and lipids Outstanding pH and lifetime stability due to Scepter organic silica hybrid packing   Superior Sensitivity and Separation Performance in Nucleic Acid Analysis Shim-pack Scepter Claris C18-120 with the bioinert coating and Scepter C18-120 with traditional stainless steel hardware were compared in this example of an analysis of a synthetic oligonucleotide. Results from Claris were highly sensitive and reproducible from the rst injection, with no loss of sample signal. Scepter C18-120 in a stainless steel column body produced low-sensitivity results and showed adsorption from the first sample injection. Outstanding Performance in Oligonucleic Acid Analysis Shim-pack Scepter Claris C18-120 (bioinert coating) and Scepter C18-20 (stainless steel body) were compared in this analysis of Oligodeoxythymidylic acid [d(T)20]. Results from Scepter C18-120 show low peak intensity, suggesting adsorption on metal surfaces. In contrast, Scepter Claris C18-120 produced a sharper and high-intensity peak. Improved Sensitivity and Separation of Phospholipids Shim-pack Scepter Claris C18-120 minimizes metal-mediated adsorption and hydrophobic absorption on the column surfaces, resulting in high-resolution separations. In this example of structurally complex phosphatidylcholine isomers, Scepter Claris C18-120 achieved increased baseline resolution between isomers with higher sensitivity.  

View product
Scepter_1
Shim-pack Scepter Claris Phenyl-120, 3um, 4.6x50

Part No.: 227-31215-07

Shim-pack Scepter

Shim-pack Scepter Claris features a column body with a newly-developed bioinert coating packed with Scepter series stationary phases. Bioinert coating is applied to the column body and stainless steel frit Ideal for analysis of metal-coordinating and hydrophobically adsorbing compounds such as nucleic acids, proteins, and lipids Outstanding pH and lifetime stability due to Scepter organic silica hybrid packing   Superior Sensitivity and Separation Performance in Nucleic Acid Analysis Shim-pack Scepter Claris C18-120 with the bioinert coating and Scepter C18-120 with traditional stainless steel hardware were compared in this example of an analysis of a synthetic oligonucleotide. Results from Claris were highly sensitive and reproducible from the rst injection, with no loss of sample signal. Scepter C18-120 in a stainless steel column body produced low-sensitivity results and showed adsorption from the first sample injection. Outstanding Performance in Oligonucleic Acid Analysis Shim-pack Scepter Claris C18-120 (bioinert coating) and Scepter C18-20 (stainless steel body) were compared in this analysis of Oligodeoxythymidylic acid [d(T)20]. Results from Scepter C18-120 show low peak intensity, suggesting adsorption on metal surfaces. In contrast, Scepter Claris C18-120 produced a sharper and high-intensity peak. Improved Sensitivity and Separation of Phospholipids Shim-pack Scepter Claris C18-120 minimizes metal-mediated adsorption and hydrophobic absorption on the column surfaces, resulting in high-resolution separations. In this example of structurally complex phosphatidylcholine isomers, Scepter Claris C18-120 achieved increased baseline resolution between isomers with higher sensitivity.  

View product
Scepter_1
Shim-pack Scepter Claris Phenyl-120, 3um, 4.6x100

Part No.: 227-31215-08

Shim-pack Scepter

Shim-pack Scepter Claris features a column body with a newly-developed bioinert coating packed with Scepter series stationary phases. Bioinert coating is applied to the column body and stainless steel frit Ideal for analysis of metal-coordinating and hydrophobically adsorbing compounds such as nucleic acids, proteins, and lipids Outstanding pH and lifetime stability due to Scepter organic silica hybrid packing   Superior Sensitivity and Separation Performance in Nucleic Acid Analysis Shim-pack Scepter Claris C18-120 with the bioinert coating and Scepter C18-120 with traditional stainless steel hardware were compared in this example of an analysis of a synthetic oligonucleotide. Results from Claris were highly sensitive and reproducible from the rst injection, with no loss of sample signal. Scepter C18-120 in a stainless steel column body produced low-sensitivity results and showed adsorption from the first sample injection. Outstanding Performance in Oligonucleic Acid Analysis Shim-pack Scepter Claris C18-120 (bioinert coating) and Scepter C18-20 (stainless steel body) were compared in this analysis of Oligodeoxythymidylic acid [d(T)20]. Results from Scepter C18-120 show low peak intensity, suggesting adsorption on metal surfaces. In contrast, Scepter Claris C18-120 produced a sharper and high-intensity peak. Improved Sensitivity and Separation of Phospholipids Shim-pack Scepter Claris C18-120 minimizes metal-mediated adsorption and hydrophobic absorption on the column surfaces, resulting in high-resolution separations. In this example of structurally complex phosphatidylcholine isomers, Scepter Claris C18-120 achieved increased baseline resolution between isomers with higher sensitivity.  

View product
Scepter_1
Shim-pack Scepter Claris Phenyl-120, 3um, 4.6x150

Part No.: 227-31215-09

Shim-pack Scepter

Shim-pack Scepter Claris features a column body with a newly-developed bioinert coating packed with Scepter series stationary phases. Bioinert coating is applied to the column body and stainless steel frit Ideal for analysis of metal-coordinating and hydrophobically adsorbing compounds such as nucleic acids, proteins, and lipids Outstanding pH and lifetime stability due to Scepter organic silica hybrid packing   Superior Sensitivity and Separation Performance in Nucleic Acid Analysis Shim-pack Scepter Claris C18-120 with the bioinert coating and Scepter C18-120 with traditional stainless steel hardware were compared in this example of an analysis of a synthetic oligonucleotide. Results from Claris were highly sensitive and reproducible from the rst injection, with no loss of sample signal. Scepter C18-120 in a stainless steel column body produced low-sensitivity results and showed adsorption from the first sample injection. Outstanding Performance in Oligonucleic Acid Analysis Shim-pack Scepter Claris C18-120 (bioinert coating) and Scepter C18-20 (stainless steel body) were compared in this analysis of Oligodeoxythymidylic acid [d(T)20]. Results from Scepter C18-120 show low peak intensity, suggesting adsorption on metal surfaces. In contrast, Scepter Claris C18-120 produced a sharper and high-intensity peak. Improved Sensitivity and Separation of Phospholipids Shim-pack Scepter Claris C18-120 minimizes metal-mediated adsorption and hydrophobic absorption on the column surfaces, resulting in high-resolution separations. In this example of structurally complex phosphatidylcholine isomers, Scepter Claris C18-120 achieved increased baseline resolution between isomers with higher sensitivity.  

View product