Gas Chromatography Consumables & Supplies
Product Listing
-
Description:
Non-polar phase: Crossbond™ 100% dimethyl polysiloxane General-purpose columns for solvent impurities, PCB congeners (e.g., Aroclor mixes), simulated distillation, arson accelerants, gases, natural gas odorants, sulfur compounds, essential oils, hydrocarbons, semi-volatiles, pesticides, oxygenates. Equivalent to USP G1, G2, G38 phases. Similar phases: HP-1, DB-1, CP Sil 5 CB, SPB-1, Rtx-1
OUT OF STOCKNon-polar phase: Crossbond™ 100% dimethyl polysiloxane General-purpose columns for solvent impurities, PCB congeners (e.g., Aroclor mixes), simulated distillation, arson accelerants, gases, natural gas odorants, sulfur compounds, essential oils, hydrocarbons, semi-volatiles, pesticides, oxygenates. Equivalent to USP G1, G2, G38 phases. Similar phases: HP-1, DB-1, CP Sil 5 CB, SPB-1, Rtx-1
-
Description:
Mid-polarity phase: Crossbond™ 6% cyanopropylphenyl / 94% dimethyl polysiloxane Application-specific columns for volatile organic pollutants. Recommended in U.S. EPA methods for volatile organic pollutants. Equivalent to USP G43 phase. Similar phases: HP-624, DB-624, DB-624 UI, VF-624ms, SPB-1301
OUT OF STOCKMid-polarity phase: Crossbond™ 6% cyanopropylphenyl / 94% dimethyl polysiloxane Application-specific columns for volatile organic pollutants. Recommended in U.S. EPA methods for volatile organic pollutants. Equivalent to USP G43 phase. Similar phases: HP-624, DB-624, DB-624 UI, VF-624ms, SPB-1301
-
Description:
Non-polar phase: Crossbond™ 100% dimethyl polysiloxane General-purpose columns for solvent impurities, PCB congeners (e.g., Aroclor mixes), simulated distillation, arson accelerants, gases, natural gas odorants, sulfur compounds, essential oils, hydrocarbons, semi-volatiles, pesticides, oxygenates. Equivalent to USP G1, G2, G38 phases. Similar phases: HP-1, DB-1, CP Sil 5 CB, SPB-1, Rtx-1 Integrated Guard Columns No leaks for a more robust method. No column connections for easier, faster maintenance. No peak distortions due to connector dead volume and thermal capacity. For column without Integra-Guard column, please refer to 221-75732-30
OUT OF STOCKNon-polar phase: Crossbond™ 100% dimethyl polysiloxane General-purpose columns for solvent impurities, PCB congeners (e.g., Aroclor mixes), simulated distillation, arson accelerants, gases, natural gas odorants, sulfur compounds, essential oils, hydrocarbons, semi-volatiles, pesticides, oxygenates. Equivalent to USP G1, G2, G38 phases. Similar phases: HP-1, DB-1, CP Sil 5 CB, SPB-1, Rtx-1 Integrated Guard Columns No leaks for a more robust method. No column connections for easier, faster maintenance. No peak distortions due to connector dead volume and thermal capacity. For column without Integra-Guard column, please refer to 221-75732-30
-
Description:
Tested with a basic amine test mix. Excellent inertness for basic compounds. Recommended for use with SH-5 Amine, SH-35 Amine, SH-Volatile Amine, and SH-PolarX capillary columns. Batch test chromatogram included. Maximum temperature: 315 °C. Chemists using guard columns in the analyses of basic compounds frequently observe peak tailing and low recovery. This happens because conventionally deactivated tubing surfaces can be adsorptive to basic compounds. Shimadzu offers basedeactivated guard columns, as well as base-deactivated inlet liners, for completely inert sample pathways.
OUT OF STOCKTested with a basic amine test mix. Excellent inertness for basic compounds. Recommended for use with SH-5 Amine, SH-35 Amine, SH-Volatile Amine, and SH-PolarX capillary columns. Batch test chromatogram included. Maximum temperature: 315 °C. Chemists using guard columns in the analyses of basic compounds frequently observe peak tailing and low recovery. This happens because conventionally deactivated tubing surfaces can be adsorptive to basic compounds. Shimadzu offers basedeactivated guard columns, as well as base-deactivated inlet liners, for completely inert sample pathways.
-
Description:
Tested with a basic amine test mix. Excellent inertness for basic compounds. Recommended for use with SH-5 Amine, SH-35 Amine, SH-Volatile Amine, and SH-PolarX capillary columns. Batch test chromatogram included. Maximum temperature: 315 °C. Chemists using guard columns in the analyses of basic compounds frequently observe peak tailing and low recovery. This happens because conventionally deactivated tubing surfaces can be adsorptive to basic compounds. Shimadzu offers basedeactivated guard columns, as well as base-deactivated inlet liners, for completely inert sample pathways.
OUT OF STOCKTested with a basic amine test mix. Excellent inertness for basic compounds. Recommended for use with SH-5 Amine, SH-35 Amine, SH-Volatile Amine, and SH-PolarX capillary columns. Batch test chromatogram included. Maximum temperature: 315 °C. Chemists using guard columns in the analyses of basic compounds frequently observe peak tailing and low recovery. This happens because conventionally deactivated tubing surfaces can be adsorptive to basic compounds. Shimadzu offers basedeactivated guard columns, as well as base-deactivated inlet liners, for completely inert sample pathways.
-
Description:
Tested with a basic amine test mix. Excellent inertness for basic compounds. Recommended for use with SH-5 Amine, SH-35 Amine, SH-Volatile Amine, and SH-PolarX capillary columns. Batch test chromatogram included. Maximum temperature: 315 °C. Chemists using guard columns in the analyses of basic compounds frequently observe peak tailing and low recovery. This happens because conventionally deactivated tubing surfaces can be adsorptive to basic compounds. Shimadzu offers basedeactivated guard columns, as well as base-deactivated inlet liners, for completely inert sample pathways.
OUT OF STOCKTested with a basic amine test mix. Excellent inertness for basic compounds. Recommended for use with SH-5 Amine, SH-35 Amine, SH-Volatile Amine, and SH-PolarX capillary columns. Batch test chromatogram included. Maximum temperature: 315 °C. Chemists using guard columns in the analyses of basic compounds frequently observe peak tailing and low recovery. This happens because conventionally deactivated tubing surfaces can be adsorptive to basic compounds. Shimadzu offers basedeactivated guard columns, as well as base-deactivated inlet liners, for completely inert sample pathways.
-
Description:
Polar polyethylene glycol deactivation Tested with a comprehensive test mix to ensure high inertness. Polyethylene glycol deactivation layer provides optimum wettability for polar compounds. Minimize peak splitting when using polar solvents such as methanol or water. Compatible with SH-PolarWax, SH-225 and SH-2330 capillary columns. Maximum temperature: 280 °C.
OUT OF STOCKPolar polyethylene glycol deactivation Tested with a comprehensive test mix to ensure high inertness. Polyethylene glycol deactivation layer provides optimum wettability for polar compounds. Minimize peak splitting when using polar solvents such as methanol or water. Compatible with SH-PolarWax, SH-225 and SH-2330 capillary columns. Maximum temperature: 280 °C.
-
Description:
Polar polyethylene glycol deactivation Tested with a comprehensive test mix to ensure high inertness. Polyethylene glycol deactivation layer provides optimum wettability for polar compounds. Minimize peak splitting when using polar solvents such as methanol or water. Compatible with SH-PolarWax, SH-225 and SH-2330 capillary columns. Maximum temperature: 280 °C.
OUT OF STOCKPolar polyethylene glycol deactivation Tested with a comprehensive test mix to ensure high inertness. Polyethylene glycol deactivation layer provides optimum wettability for polar compounds. Minimize peak splitting when using polar solvents such as methanol or water. Compatible with SH-PolarWax, SH-225 and SH-2330 capillary columns. Maximum temperature: 280 °C.
-
Description:
Polar polyethylene glycol deactivation Tested with a comprehensive test mix to ensure high inertness. Polyethylene glycol deactivation layer provides optimum wettability for polar compounds. Minimize peak splitting when using polar solvents such as methanol or water. Compatible with SH-PolarWax, SH-225 and SH-2330 capillary columns. Maximum temperature: 280 °C.
OUT OF STOCKPolar polyethylene glycol deactivation Tested with a comprehensive test mix to ensure high inertness. Polyethylene glycol deactivation layer provides optimum wettability for polar compounds. Minimize peak splitting when using polar solvents such as methanol or water. Compatible with SH-PolarWax, SH-225 and SH-2330 capillary columns. Maximum temperature: 280 °C.
-
Description:
Midpolarity Crossbond™ phase General-purpose columns for alcohols, oxygenates, PCB congeners (e.g., Aroclor mixes), and pesticides. Equivalent to USP G46 phase. 4.5" standard coil diameter. Similar phase: DB-PS1701
OUT OF STOCKMidpolarity Crossbond™ phase General-purpose columns for alcohols, oxygenates, PCB congeners (e.g., Aroclor mixes), and pesticides. Equivalent to USP G46 phase. 4.5" standard coil diameter. Similar phase: DB-PS1701
-
Description:
Polar phase; Crossbond™ Carbowax polyethylene glycol—provides oxidation resistance General-purpose columns for FAMEs, flavor compounds, essential oils, amines, solvents, xylene isomers, and U.S. EPA Method 603 (acrolein/acrylonitrile). Equivalent to USP G14, G15, G16, G20, and G39 phases. 4.5" standard coil diameter.
OUT OF STOCKPolar phase; Crossbond™ Carbowax polyethylene glycol—provides oxidation resistance General-purpose columns for FAMEs, flavor compounds, essential oils, amines, solvents, xylene isomers, and U.S. EPA Method 603 (acrolein/acrylonitrile). Equivalent to USP G14, G15, G16, G20, and G39 phases. 4.5" standard coil diameter.
-
Description:
General-purpose columns with unique selectivity for pesticides, PAHs, or other semivolatiles. Ideal for low/trace-level analyses. Low-bleed, high-resolution columns with unique selectivity.
OUT OF STOCKGeneral-purpose columns with unique selectivity for pesticides, PAHs, or other semivolatiles. Ideal for low/trace-level analyses. Low-bleed, high-resolution columns with unique selectivity.
Precision and result consistency are paramount in gas chromatography (GC). The quality of consumables significantly influences result quality. ShopShimadzu’s commitment to excellence in GC supplies is founded on several key factors that set our products apart as exemplars of quality.
Precision engineering forms the cornerstone of our GC supplies, ensuring consistent and accurate outcomes. We employ superior materials that resist degradation and withstand the demands of chromatographic analysis.
Our manufacturing process includes rigorous quality control, guaranteeing the reliability and uniformity of each supply. Our GC supplies are designed to accommodate various applications, from volatile organic compounds to permanent gases, catering to the needs of analytical professionals.
Our commitment extends beyond our products. ShopShimadzu offers expert technical support to assist you in selecting the right supplies, optimising methodologies, and overcoming challenges. ShopShimadzu’s chromatography consumables excel due to precision engineering, superior materials, stringent quality control, versatility, and comprehensive technical support. Our range of gas chromatography supplies is the preferred choice of analytical professionals pursuing the highest standards in chromatographic analyses.
Gas Chromatography Supplies Overview
ShopShimadzu offers a comprehensive range of high-quality GC supplies, including guard columns, capillary columns, PLOT columns, metal columns, GC gas filters, GC inlet liners, SPME Arrow/Fiber products, and various accessories. The quality of these supplies is crucial for achieving accuracy and reliability in chromatographic analyses.
ShopShimadzu’s commitment to excellence ensures that these chromatography consumables uphold the highest standards, guaranteeing precision and consistency in your analytical processes. Our comprehensive range of GC supplies covers various categories, each tailored to specific analytical needs.
Guard Columns
Guard columns are essential components in gas chromatography, safeguarding the primary analytical column from contamination. ShopShimadzu’s guard column supplies play a vital role in preserving the integrity of your analytical process, ensuring the precision and consistency of results, mainly when dealing with complex samples.
Capillary Columns
Capillary columns are the cornerstone of GC, facilitating precise separation of intricate mixtures. ShopShimadzu’s capillary columns are highly regarded for their extraordinary precision, proving indispensable in many analytical applications necessitating high-resolution separations for achieving unmatched analytical precision.
PLOT Columns
Porous Layer Open Tubular or PLOT columns are engineered for specialised applications, stand out with their distinctive porous structure. Their exceptional ability to separate permanent gases and specific analytes makes them ideal for tackling demanding analytical tasks, ensuring precision in even the most challenging analysis.
Metal Columns
Metal columns are robust and resilient, making them an ideal solution for applications requiring durability and longevity. ShopShimadzu’s metal columns consistently deliver unwavering performance, ensuring reliable results, even when operating in the most demanding and challenging environments.
GC Gas Filters
GC gas filters play a pivotal role in upholding the purity of carrier gases, thus safeguarding your analytical instruments and securing the accuracy of your results. They are indispensable components in chromatographic analyses, ensuring the reliability and consistency of your analytical processes.
GC Inlet Liners
GC inlet liners are your samples' first point of contact, and their quality is essential. They prevent sample contamination, ensuring that your analyses begin with precision and accuracy. ShopShimadzu’s GC inlet liners and chromatography consumables are meticulously crafted to uphold consistent, reliable performance, setting the foundation for precise analytical results.
SPME Arrow/Fiber
Solid Phase Microextraction (SPME) Arrow/Fiber products revolutionise sample preparation by streamlining the process. They facilitate efficient extraction and concentration of analytes, simplifying your workflow and enhancing the overall analytical process. ShopShimadzu’s SPME products are designed to optimise efficiency and accuracy in your analytical endeavours.
GC Accessories
GC accessories comprise various essential components, from septa to ferrules, designed to complete your analytical toolkit. These meticulously crafted accessories are instrumental in ensuring the meticulous management of every aspect of your analytical process, facilitating precision and accuracy in your results.
High Quality GC Supplies for High Accuracy
At ShopShimadzu, our gas chromatography supplies are not just products but a testament to our dedication to excellence. We understand that the reliability of your analyses hinges on the quality of your consumables, and our GC supplies are engineered to deliver nothing less than perfection.
When it comes to high-quality GC supplies, ShopShimadzu is your trusted partner. Our products are reliable and backed by technical expertise that ensures their performance. From GC columns and custom packed columns to HPLC columns and GC syringes, every product in our consumables catalogue is designed to elevate your analytical accuracy.
Choose ShopShimadzu for your GC supplies, and experience the difference that quality makes in achieving precision and reliability in your laboratory. Your analytical success is our mission, and our GC supplies are the tools that help you achieve it.
Trust ShopShimadzu, a leading supplier of laboratory consumables in Singapore, for all your chromatography consumable needs. Explore our extensive range today and improve the efficiency and accuracy of your analytical processes.